Non-Invasive Blood Pressure (NIBP) – Patented Colin Technology
Measurement technology Oscillometric method
Measurement method Linear deflation method
Pressure display range 10 to 300mmHg
Pressure display accuracy Less than ±3mmHg
NIBP Measurement range
Adult/pediatric mode
SYS 60 to 250mmHg
MAP 45 to 235mmHg
DIA 40 to 200mmHg
Pulse rate 40 to 200bpm
Neonatal mode
SYS 40 to 120mmHg
MAP 30 to 100mmHg
DIA 20 to 90mmHg
Pulse rate 40 to 240bpm
NIBP accuracy AAMI SP-10:2002+A1:2003
Pulse rate accuracy ±2% or ±2 beats
ECG (Electrocardiogram)
Leads 3/5 Lead
Lead I, II, III, aVR, aVL, aVF, V (Chest Lead)
Heart Rate
Measurement Range 20 to 250bpm
Accuracy ±3bpm or ±5% (whichever is greater)
Respiration (im RR)
Measurement method Trans-thoracic impedance
Leads RA to LA
Range 0, 3 to 120breaths/min
Accuracy ±3 breaths/min
SpO2 (Pulse oximeter)
Measurement method 2 wave length pulse wave type
Range 1 to 100% SpO2
Accuracy Adult/pediatric (When using SpO2 Disposable Sensor MAX-A) 70 to 100% SpO2 ±2 digits, 1 to 69% SpO2 unspecified
Pulse Rate Range 20 to 250bpm
Pulse Rate Accuracy ±3bpm
Display update Less than 30 sec
Temperature Measurement (Option)
Measurement method Thermistor
Probe Type Thermistor probe YSI 400 series (2 channels) (Probes not included)
Range 15 to 45°C (59 to 113°F)
Display Accuracy ±0.1°C (25 to 45°C) (77 to 113°F) ±0.2°C (15 to less than 25°C) (59 to less than 77°F)
Probe Accuracy ±0.1°C (±0.18°F)
IBP (Option)
Measurement Method: Pressure Transducer Method
Pressure Measurement Range – -50 to +300mmHG
Pulse Rate Measurement Range – 20 to 250bpm
Display Accuracy – ±3mmHG
Standard – IEC60601-2-34:2000
CO2 (Option)
Measurement method Non-dispersive Infrared Spectroscopy
Range 0-100mmHg : 0-13.3kpa : 0-10%CO2
Accuracy ±2mmHg or ±4% (whichever is greater)
Respiration (awRR) Range 0 to 120 breaths/min
Respiration (awRR) Accuracy ±1 breath/min
Recorder (Option)
Type Thermal
Weight 150g (0.33lbs)
Resolution 8 dot/mm
Number of channels 1 to 2 channels
Paper Type Thermal
Paper Width 50mm (2in)
Paper Speeds 25.0mm/sec and 50.0mm/sec (1in/sec and 2in/sec)
General
Dimensions 360(W) x 215(D) x 280(H)mm (14.2 x 8.5 x 11in)
Weight 5.5kg (12.1lbs) (excluding optional configurations and accessories)
Display – Screen Size 26.4cm (10.4in) measured diagonally, Screen Type/Color Liquid Crystal Display (LCD) color, Resolution 800 x 600 pixels
Number of traces 4 or 6 waveforms
Safety Standard IEC60601-1:1988+A1:1991+A2:1995
Degree of protection (enclosures) IP21
Type of protection Type CF – Applied part
Power Requirement
AC Power 100-240V~50/60Hz, 0.5-1.3A
Battery Ni-MH, 12V/3.8Ah (1 included)
Environmental
Operating Temperature 10 to 40°C (50 to 104°F)
Storage Temperature -20 to 60°C (-4 to 140°F)
Operating Humidity 15 to 90% RH, non-condensing
Accessories
Most models: Reusable adult cuff, adult 3.5m cuff hose, ECG cable,
ECG 3-lead wires, SpO2 Durasensor® DS-100A, SpO2 extension cable
DOC-10, operation manual, power cord, rechargeable battery (1).
Available with: CO2 sampling set, printer paper, ECG 5-lead wires,
temperature probes, rolling stand, and a full size range of reusable and
disposable BP cuffs